Bio Safety Cabinet Class II /A2 Type 960W,(South Korea)

Product Overview

Class ll type A2 biological safety cabinet that protects the user and lab environment from the biohazard factor and prevents cross-contamination of various samples used in experiments.

Suitable for laboratories requiring higher levels of safety grade 2

Intake air and working chamber air are drawn to the under plenum of

the worktop bench ensuring user safety is assured.

70% recirculated air is filtered with the HEPA filter, ensuring product safety is assured.

30% exhausting air is emitted through the HEPA filter, which complies with

the environmental safety requirements of the laboratory.

Equipment that enables safe UV sterilizer

UV sterilization will affect microorganisms at the surface of the work table.

While UV light is on, the front reinforcement glass door protects the user by blocking UV rays.

Automatically turn off UV light when opening the door or turning on the fluorescent lamp.

Checking the life and performance of filters through a differential pressure gauge

Measure the pressure of the bottom HEPA filter to check the performance and lifespan of

the filter in real-time, allowing more safe and effective testing.

Front-side 10-degree tilting design for user’s convenience

Ergonomic 10degrees tilting design allows users to make a convenient posture during the experiment,

which enables the user’s neck, shoulders, and back comfortable despite long work with the cabinet.

Also, the user’s eyes can be protected from the reflection of light on the glass surface by this tilting design.

Strengthen sample and user safety

Protect specimen and user’s safety by inflow and downflow control.

Internal air pressure is maintained with negative pressure compared to the outside, preventing

the contaminated air from escaping through the gaps.

High-performance motor to maintain the set airflow velocity

Regardless of filter loads, airflow velocity can be maintained at the set value through

the high-performance motor

Easy and quick maintenance due to short filter replacement time

The filters can be replaced in any direction in front or upper of the cabinet, minimizing the time required

for maintenance to be maintained regardless of the installation conditions.

Strengthen validation support using higher performance filters

HEPA filter that enables to remove 99.995% of particles that

have a size greater than or equal to 0.3

Optional ULPA filter that enables to remove 99.9995%

of particles that have a size greater than or equal to 0.12